Operating Instructions
Check and top up the
battery's fluid level
Note!
! Regularly check the fluid level of
acid-filled batteries.
! Screw out all cell plugs
! If the fluid level is too low fill up
cells with distilled water up to
mark
! Charge the battery
! Screw in the cell plugs
KM 100/100 R B / KM 100/100 R LPG
Checking the fuel tank level
– applies only to
KM 100/100 R B
! Open unit cover, engage stay bar
Fill level indicator
Refuelling – applies only to
KM 100/100 R B
Danger!
Explosion hazard
— Do not fill-in fuel in closed rooms
! Shut-off the engine
— Smoking and naked flames
prohibited
! Open tank cap
! Refuel with "unleaded premium
petrol"
! Fill tank to a maximum of 1 cm
below the bottom edge of the
filler pipe
! Wipe off overflowed fuel and
close tank cap
Checking the gas filter –
applies only to
KM 100/100 R LPG
! Check gas filter in the threaded
connection to the gas cylinder for
dirt
! Clean a dirty filter with
compressed air
Checking gas lines –
applies only to
KM 100/100 R LPG
! Check gas connections, gas
lines, and carburettor with leak
detector spray for leaks
Note:
Leakages lead to icing or yellow,
foamed deposits at the gas
connections, the gas lines and at
the evaporator.
Consult the Kärcher service station
for maintenance of the gas system
English
Check the tyre air pressure
! Set inflation pressure of front tyre
to 6 bar.
! The air pressure in the rear tyres
must be set to 6 bar.
35