Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

76
5-40
5-41
5-42
Operation
5.12

Special functions

In this chapter all functions that may be accessed by
the operator are described. A function is a "mode" that
is not required to balance a wheel properly.
5.12.1 User function
Use this function to store or recall rim data (wheel type,
diameter, width, Offset, fi ne mode, oz mode and mm
mode) in or from the memory. 4 sets of wheel data (the
+
so-called user data) can be stored.
When it is turned ON the balancer sets the wheel data
regarding user A to the system default values and sets
the current user to user A.
To activate:
• Press the "*" and the weight keys simultaneously
for 3 seconds. See Figure 5-40.
The function starts with the SAVE option.
The data can be saved to the user displayed on the
right. Refer to Figure 5-40 for the default setting.
To clear the data (without saving):
• Select Enter when user "- -" is displayed. Refer to
Figure 5-41.
To save data:
• Select + or – to scroll along User A, b, C or d.
• Select Enter to save to the selected user.
The function proceeds with the RECALL option.
The data can be recalled from memory by selecting
the appropriate user. The selected user will be the
new current user, e.g. User b.
No recall required (no change in user required):
• Select Enter when user "- -" is displayed.
To recall data:
• Select + or – to scroll along User A, b, C or d.
• Select Enter to recall the selected user.
The current available wheel data will be replaced
by the recalled data (e.g.: "b" Figure 5-42).
...

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis