1
2
3
48
5-17
5-18
5-19
5-20
5-21
Operation
5.9
Weight application
The following weight types and application methods
are available:
-
clip-on weights:
Always apply by hand
-
stick-on weights:
Must be applied by hand
gauge head, for the Alu 2P, Alu 3P or HWM mode.
Hand applied weights must be applied
Note:
exactly perpendicular to the shaft (in the
top position using the arm, in 5 o'clock
position using Laser Pointer).
After spinning the wheel look at the rotation indicators
for the left plane of the wheel
As the correct wheel angle position gets closer a
further indicator lights up. When all the indicators are
ON (2, Fig. 5-20), the WAP indicator will also light up
(3-Figura 5-20).
When the correct angle is reached all the
Note:
rotation indicators should be ON. If the
wheel has been pushed too far, only the
indicators of the other half will come ON
(Figura 5-21). If this happens, the wheel
must be delicately turned in the opposite
direction until the WAP position is reached.
The weight to be applied in that plane is shown on
the display.
Attaching a clip-on weight.
Refer to Figure 5-17.
• Clip-on weights must always be applied in the 12
o'clock position.
• The lip should rest on the rim edge. Use the weight
pliers to position it.
In STATIC mode only the left hand display is used.
Attaching a stick-on weight.
ALU or STATIC weight modes only:
Refer to Figure 5-18.
• Apply the weight on the rim in the 12 o'clock
position, always by hand.
With STATIC weight modes, always apply the
Note:
weight at the rim centre line. If not possible,
split the weights evenly and apply on another
surface of the rim (symmetrical to the rim
centre line).
...
(Fig.
5-17).
(Fig.
5-18), or using the
(1, Fig.
5-19):