Wiring according to EMC (installation of a CE−typical drive system)
Conditions for trouble−free operation:
l
Except for the mains cable, use shielded cables only.
l
The shield must be carefully connected to PE (see below).
l
Connect motor and mains PE conductors to separate PE terminals.
a
B
X1
f
D
X2
e
e
Fig. 24
Wiring according to EMC
0
Connection cable for relay
1
Mains cables L1, L2, L3, PE (loop through 2 cables to the mains)
2
PE connection for mains cables
3
Shielded control cables; fix the shield tightly to the sheet with the
cable tie
4
Shielded control cables
5
Isolated terminal (e.g. star point for star connected motor)
X1
Terminal strip − mains connection
X2
Terminal strip − motor connection
PES HF shield connection by PE connection to the shield
1) applies to device versions 001 and 151
2) applies to device versions 152 and 153
L
efesotomasyon.com - Lenze
Shield connection:
1. Prepare the cable
B
2. Insert the cable tie
c
3. Lay the cable into the
cable tie and tighten it.
The shield must be
tightly connected to
the shield sheet.
e
82mot395
1
or electronic switching output
EDK82MV752 DE/EN/FR 6.0
Installation
motec with motor or geared motor
6