Herunterladen Inhalt Inhalt Diese Seite drucken

Preparation - Lenze 8200 motec Montageanleitung

Vorschau ausblenden Andere Handbücher für 8200 motec:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

3.2.2

Preparation

(
Fig. 26
Wall mounting of the motec
1. Pre−assembling of the adapter plate:
– Pull the adapter plate into the fixture of the fan module by means of two screws M5 x 65
– Remove the screws
2. Mount the fan module on the wall with appropriate screws
3. Mark the position of the cable glands on the carrier housing and cut out the openings
4. Insert the cable glands
5. Place the carrier housing onto the fan module and screw it with 4 screws M5 x 65 mm (scope
of supply) onto the fan module
6. Cables which are led into the carrier housing must be stripped. The following applies to all
shielded cables:
– Strip 10 cm of the cable sheath
– Remove the shielding of the cable cores on a length of 8 cm
– 2 cm of the shield are needed for safe shield connection
L
efesotomasyon.com - Lenze
Stop!
The motec can be destroyed by thermal overload!
In case of wall mounting, the fan module E82ZMV must be mounted additionally for
ensuring a sufficient cooling of the motec
EDK82MV752 DE/EN/FR 6.0
Installation
Wall mounting
8200mot402
73

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis