Heaty Racun 300 Advanced Plus | Maintenance and repair
5
Turn the head counterclockwise to loosen the head.
6
Pull the head with the suction lance out of the cartridge.
7
Remove the refill pack with mixed bed resin from the outer packaging
and bring the outer packaging in a sufficiently large container.
8
Empty the exhausted mixed bed resin from the composite container into
the container with the outer packaging:
The mixed bed resin is retained by the outer packaging and the
water collects in the container.
9
Dispose of the mixed bed resin and empty the water into a drain.
10
Open the refill pack with mixed bed resin and fill it with using a funnel,
pour the liquid into the cartridge. Compact the mixed bed resin
if necessary, shake or rotate the cartridge.
50
Maintenance and repair | Heaty Racun 300 Advanced Plus
11
Fill the cartridge to a height of approximately 2 cm below the
thread with water.
12
Stir the mixed bed resin with a pipe or other
suitable tool to insert the head with suction lance more easily.
13
Reinsert the head with suction lance into the cartridge.
14
Turn the head clockwise until hand-tight.
The mixed bed resin has been changed and the cartridge is
working again at full capacity.
6.2.2 MAGella twister maintenance
Technical information on the MAGella twister can be found in section "9.2 MAGel-
la twister" on page 60.
6.2.3 Change dual filter and clean Magnetraw
NOTE
The dual filter must be checked and, if necessary, replaced before the device
is installed in a heating or cooling system.
At the latest after the processing of 1,100 m³ Water the dual filter must be
changed.
1. Close the inlet and
1.
outlet valves. Open
the fill and drain valve
to release the pressu-
re. Then open the vent
tap on top of the filter.
Turn the wing nut and
remove the cap
3.
3. Then remove the
compression
spring
and clean with water it
if necessary.
The assembly takes place in reverse order.
The twister insert on the magnetic rod should be directed towards the entrance to achieve the highest capacity.
2. Remove the mag-
2.
netic rod and clean
it, for example with a
cloth.
4.
4. Now you can re-
move and replace the
basket with the dual
filter bag (spare part
number 100454)
51