Heaty Racun 300 Advanced Plus | Operation
5.1.3 Settings
Measurement delay
The measurement delay function is used to set the measurement delay when there
is a long connection line between the device and the heating or cooling system.
This function takes into account the amount of water in a long pipe from the device.
Start desalination
The Start Desalination function sets the limit value for conductivity in the range of
30-500 μS.
Hysteresis desalination
The desalination hysteresis function is used to set the tolerance for the desalination
start in the range of 1-95 μS to prevent the treatment from constantly starting and
stopping.
Example: With a set start desalination of 100 μS and a hysteresis of 20 μS, the treat-
ment will only be reactivated when the conductivity reaches 120 μS or deactivated
when the conductivity reaches 80 μS.
Delay desalination
The desalination delay depends on the size of the cartridge and is preset by the
manufacturer.
Limit temperature
The temperature limit function specifies a water temperature limit (max. 80°C) upon
which the device is switched off.
Maximum conductivity from cartridge
With the Maximum Conductivity from Cartridge function, a limit for the consump-
tion of the cartridge can be set and thus the treatment can be controlled. Recom-
mendation: Factory setting of 60 μS.
Maximum replenishment
The Maximum Make-Up function specifies a limit for the make-up in litres/week. Ex-
ceeding this limit may indicate a pipe break, leak or similar and will result in the so-
lenoid valve shutting off the water make-up. If the limit value is exceeded, an alarm
is signaled on the flow chart with status display (see section "3.7 Touch display" on
page 20) and, if necessary, transmitted to the building management system.
Cartridge protection
The cartridge protection function activates or deactivates the automatic flushing of
the cartridge and sets the interval for the automatic flushing (1-30 days).
34
5.1.4 Configuration
Operating mode
The operating mode function can be used to select between continuous operation,
normal operation and filtration modes.
Differential pressure
The differential pressure function displays the differential pressure for the degree of
contamination of the dual filter.
Reset water meter
The reset water meter function resets the internal water meter to start a new mea-
surement.
Delete make-up counter reading
The Delete make-up counter reading function resets the counter for the maximum
make-up in order to start a new measurement.
Factory settings
The basic settings are made during commissioning. These will remain until a change
occurs.
Language
Currently only German is available.
Interface communication
Fault messages can be forwarded via a potential-free contact. The connection via
Modbus is optional.
Parameter Actual States
The current status can be queried at any time by scrolling through the screen. In this
program step the cartridge protection can also be reset.
Fault indication
If the set values are outside the tolerances, an error message appears on the screen
and indicates the respective error.
Set password
Service password: available on request
Settings: the last 4 digits of the serial number (on label) - without spaces.