VOLTCRAFT RLG 7008 Bedienungsanleitung Seite 40

Reflex-ladestation
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Charging rate
typical
Quick charging time
4 C
15 mins.
2 C
30 mins.
1.3 C
45 mins.
1 C
60 mins.
C / 1.5
90 mins.
C / 2
120 mins.
C / 2.5
150 mins.
C / 3
180 mins.
C / 4
240 mins.
At a charging rate of 1 C (many accumulator manufacturers state 1 C as quick charging
rate), the charging current corresponds to the figures of the nominal capacity. An
accumulator with a nominal capacity of 1.5Ah would then ti be charged with a charging
current of 1.5A .
As the charging effect degree of an accumulator is always less than 100%, more energy always
has to be fed than the accumulator is actually able to store. The charge quantity which has to be
fed is up to 1.4 times as great as the nominal capacity of the accumulator which is printed on its
housing.
This has to be taken into consideration correspondingly of course for the charging time.
• The setting is terminated with the key "Eingabe".
• If you wish to check the figures or alter them once again, just press the key "Eingabe" until the
desired parameters are displayed. Then proceed as described above.
40
Transitional charging-
Impulse interval
40 secs.
20 secs.
13 secs.
40 secs.
7 secs.
5 secs.
4 secs.
3 secs.
2 secs.
Retention charging-
Impulse interval
160 secs.
80 secs.
53 secs.
160 secs.
27 secs.
20 secs.
16 secs.
13 secs.
10 secs.
Safety timer
Run time
21 mins.
39 mins.
57 mins.
75 mins.
110 mins.
144 mins.
212 mins.
244 mins.
275 mins.