Press and hold the black button on the Digital display until it switches off.
5.
CHECK HUD LINK
The HUD link can be checked to ensure that the HUD is linked to the correct apparatus.
To check the HUD link, hold the backlight button for two seconds, release it for one
second and then hold it again for two seconds. After the Backlight button has been
released, the two LED lights on the righ hand side of the HUD will start to flash if it is
linked to the apparatus.
NOTE: ONLY ONE USER CAN CHECK THE HUD LINK AT THE TIME. IF SEVERAL USERS TEST THE HUD LINK AT ONCE IT WILL
BE IMPOSSILBLE TO TELL IF THE HUD IS LINKED TO THE CORRECT APPARATUS OR NOT.
BREATHING APPARATUS COMPUTER (BAC)
The BAC is measuring the pressure and supplying the information to the Digital Display
and HUD. It logs all usage data which can be accessed with a PC interface (optional).
During Run mode, the main LED flashes yellow as a position light.
In addition to the main LED, there are two yellow LEDs for added visibility.
8

CYLINDER PRESSURE WARNINGS

LOW AIR WARNING
Default value is set to 55 +/- 5 bar. It can be configured to a higher pressure (up to
75 bar).
LOW AIR WARNING INDICATION
HUD flashes the red LED or according to configured settings (if fitted with HUD)
BAC emits a warning sound
Main LED of the BAC flashes red
Display LED flashes red
MUTABLE LOW AIR WARNING (OPTIONAL)
Mute the low air warning for one minute by pressing the backlight button (section 8)
TURN-BACK SIGNAL (OPTIONAL)
It can be set as a static value between 75 and 175 bar or as a dynamic value based on
the initial cylinder pressure.
At this level the display backlight turns red and is automatically lit for 10 seconds.
If the cylinder pressure increases above the set level, the turn-back signal is re-set.
If fitted and function activated, the HUD flashes (the active pressure indication LEDs)
for 10 seconds.
NOTE: WHEN DEPRESSURIZING THE UNIT RAPIDLY AFTER USE, THE APPARATUS SOMETIMES SHUTS DOWN WITHOUT ANY
LOW AIR WARNING OR TURN BACK SIGNAL.