When operating with two separate independently valved cylinders both cylinders
must be charged with similar working pressures. Always open both cylinder valves
when pressurizing the breathing apparatus and ensure that both cylinder valves are
kept open during the use of the apparatus.
If the self contained breathing apparatus is to be used in conjunction with other
personal protective equipment it is important to ensure that the additional personal
protective equipment is compatible with the breathing apparatus and does not impair
the full protection of the respiratory protective device.
Examples of dangers which may require the use of additional personal protective
equipment:
-Liquids, steam or gases which can damage the skin
-Pollutants absorptive by skin
-Thermal radiation
-Mechanical effects
-Explosive environments
-Oxygen-enriched breathing air
1
CYLINDER MOUNTING
Place the cylinder on the backplate.
1.
Check the connection O-ring and screw the cylinder valve hand tight to the
2.
cylinder connection of the manifold block.
Fasten cylinder strap around the cylinder and hook together with the buckle.
3.
Adjust the length of the strap if needed. Do not over tighten. If the strap is over
tightened the buckle and backplate will be damaged.
Close the lever on the buckle. Make sure that the locking tab has locked the lever
4.
in the closed position. (To release the cylinder buckle the locking tab must be
pressed down.)