Disconnecting the breathing valve

Push the two red tabs together and pull the breathing valve straight out from the face mask.

Positive pressure mode

Inspire-H (with hatch)
1.
Positive pressure is activated by closing the ambient air hatch by pushing the exhalation valve
cover against the face mask.
2.
To shut off positive pressure and breathe ambient air, simultaneously press down the indicator arm
and push the exhalation valve cover away from the face mask. Positive pressure can also be shut
off by disconnecting the breathing valve from the face mask. When using the face mask in ambient
air mode the option to open the hatch should always be used as it is an easier operation and
minimizes the risk for fogging of the visor.
Inspire-A (without ambient air hatch)
1.
Positive pressure is automatically activated when connecting the breathing valve to the face mask.
2.
To switch off the positive pressure:
Disconnect the breathing valve from the face mask.
Inspire - FB (without ambient air hatch)
1.
Positive pressure is automatically activated by the first breath.