Reassemble the battery pack and insert into the BAC. Orientate the battery pack
4.
according to the markings inside the BAC and on the sides of the battery pack.
If the battery pack is correctly positioned, the BAC beeps when connected to the batteries.
Replace the battery cover and gently tighten for even gasket pressure, ensuring a
5.
good seal. Do not over-tighten the screws.
REPLACING WIRELESS HUD BATTERIES
Remove the HUD from the face mask. Refer to section 3.
1.
Using a Phillips screwdriver, unscrew the battery cover screw. [Fig. 18]
2.
Lift up the locking tab and open the battery compartment cover. [Fig. 18]
3.
Insert a AAA battery in the direction of the marking on the HUD. [Fig. 18]
4.
Close the cover and reassemble the cover with the screw. Gently tighten for even
5.
gasket pressure ensuring a good seal. Do not over-tighten.
Repeat the same procedure for the second battery on the other side.
6.
When the batteries are installed, the HUD will flash all six LEDs five times.
14
STORAGE AND TRANSPORT
Store in a cool, dry and dust-free environment. Protect rubber parts from direct
sunlight, UV radiation and direct heat. When the regulator unit is not connected, the
cylinder valve should always have a protective plug.
The unit should be stored with the face mask/breathing valve in the position for
activated positive pressure.
During transport the product must be well protected inside the original packaging
material or equivalent packaging material.
15
EXTRA AIR CONNECTION
Some models are equipped with an extra air connection which can be used to:
Connect to a chemical suit ventilation system
1.
Connect a rescue hose between two apparatuses
2.
Connect an extra mask
3.
Connect the EVAC evacuation hood
4.
Feed the apparatus from an external air source
5.
When taking air from the apparatus, point 1-4 above, the air consumption increases
and the duration of the apparatus decreases.
A special female coupling with a non-return valve opener must be used when taking
air from the apparatus, point 1-4 above. This device opens the non-return valve in the
male connection on the apparatus.
ATTENTION! WHEN FEEDING THE APPARATUS FROM AN EXTERNAL AIR SOURCE, THIS KIND OF FEMALE COUPLING MUST
NOT BE USED. IN THIS APPLICATION THE NON-RETURN VALVE IN THE MALE CONNECTION MUST BE ABLE TO CLOSE IN
CASE OF DISRUPTION IN AIR SUPPLY FROM THE EXTERNAL SOURCE.
23