Werbung

TEST OK
PRESS LEFT
FAILURE INDICATION
LOW CYL !!!
LOW BATT
LEAKAGE
CAPACITY
ADSU/PASS
1)
Replace battery immediately after the current operation or if possible before the operation is continued.
2)
Only conducted if Full Test is performed
ATTENTION! ALWAYS FOLLOW YOUR ORGANIZATION'S POLICY TO DETERMINE WHETHER AN OPERATION MAY BE
PERFORMED AFTER THE OCCURRENCE OF FAILURE INDICATION(S).
PERFORMING THE "SHORT TEST"
Open the cylinder valve fully. The display reads according to the figure below.
1.
INTERSPIRO
Check the sound.
2.
CHECK SOUND
The display reads according to the figure below for three seconds.
3.
FULL TEST
HOLD BLACK
The display reads according to the figure below for two seconds.
4.
SHORT TEST
The display will stop and show the result of the test until the backlight button is
5.
pressed. See the section titled "Test Results".
12
FAILURE
LOW CYL !!!
EXPLANATION
CYLINDER PRESSURE BELOW PRE-SET LEVEL (CONFIGURATION
DEPENDENT)
BATTERY HAS LESS THAN 2 HOURS OF OPERATION
THE UNIT FAILED THE LEAK TIGHTNESS TEST
THE UNIT FAILED THE AIR FLOW CAPACITY TEST
THE UNIT FAILED THE MOVEMENT SENSOR TEST
1)
2)
2)
2)