Troubleshooting
The following table will assist you in fixing faults:
Problem
Machine does not start
Device does not convey
water
No pressure in device
Water system leaky
Strong pressure fluctu-
ations
44
Possible cause
On/Off switch (32) turned
off
No mains power supply
Incorrect voltage supply
Air locks in the pressure
washer
Air locks in the pressure
washer
Pressure loss in line
Connections not correctly
installed
Water connection (28)
leaky
3-in-1 nozzle (23) is dirty Rinse the 3-in-1 nozzle
3-in-1 nozzle (23) clogged Remove the 3-in-1 nozzle
Error correction
Check the position of the
On/Off switch
Check the socket, mains
connection cable, plug
and fuse and have them
repaired by a qualified
electrician if necessary.
Check whether the elec-
trical system matches the
information on the type
plate
Turn the device on and
press the switch lever
(17).
Bleeding, p. 41
Bleeding, p. 41
Check the water supply
Turn off the device and
disconnect it from the
mains. Reconnect the
device to the water sup-
ply (see Establishing a
water supply, p. 38)
Turn off the device and
disconnect it from the
mains. Change the coup-
ling (29) on the water con-
nection (28) including
sealing ring (see )
(23) with water. If re-
quired, clean the nozzle
bore hole with a nozzle
cleaning needle (6; see ).
(23) and ensure that the
water can discharge from
the trigger gun (1) unim-
peded.