Bleeding the device
1. Move the On/Off switch (32) to the
position "I" (ON).
2. Wait until pressure has built up
and the motor stops.
3. Move the On/Off switch (32) to the
position "0" (OFF).
4. Press the switch lever (17) on the
trigger gun (1) until the pressure
has been released.
5. Repeat these steps several times
until there is no more air in the
device.
Ending the operation
1. After working with cleaning agents:
• Empty the cleaning agent tank
(13).
• Rinse the device with clear wa-
ter until the lines are free of
cleaning agent.
2. Release the switch lever (17).
3. Move the On/Off switch (32) to the
position "0" (OFF).
4. Close the tap.
5. Press the switch lever (17) on the
trigger gun (1) until the pressure
has been released.
6. Pull out the plug. Wind the mains
connection cable (10) on the hold-
er (11).
7. Disconnect the device from the
water supply.
Cleaning,
maintenance and
storage
 WARNING! Electric shock! Risk
of injury due to unintentional start-
up. Protect yourself when perform-
ing maintenance or cleaning work.
Switch off the device and disconnect
the mains plug from the socket.
42
You should have any repair and main-
tenance work that is not described in
these instructions carried out by our
Service Centre. Only use original re-
placement parts.
Cleaning
NOTICE! Risk of damage! Improp-
er cleaning can damage the device.
Never spray down the device with
water. Do not clean the device under
running water. Do not use any abras-
ive cleaning agents or solvents.
Always keep the device clean.
Cleaning after operation
1. Move the On/Off switch (32) to the
position "0" (OFF).
2. Pull out the plug.
3. Keep the ventilation slits clean and
free of objects.
4. Clean the device with a soft brush
or a slightly damp cloth.
Cleaning the 3-in-1 nozzle
In rare cases, the 3-in-1 nozzle may
become clogged by foreign bodies.
1. Remove the 3-in-1 nozzle (23).
2. Adjust the 3-in-1 nozzle so that the
nozzle to be cleaned and the con-
nection are in a straight line.
3. Remove the foreign body from
the front using the nozzle cleaning
needle (6).
4. Rinse the 3-in-1 nozzle with water
from the front to remove the for-
eign body.
Cleaning the filter insert in the wa-
ter connection
1. Remove the coupling (29) from the
water connection (28).
2. Remove the filter insert (30) from
the water connection.
3. Clean the filter insert under run-
ning water.
4. Fit the filter insert (30) and coup-
ling (29) in reverse order.