Herunterladen Inhalt Inhalt Diese Seite drucken

Replacing The Datamanager Card; Preparatory Work; And Finally - Fronius Primo 4.5-1 Serviceanleitung

Netzgekoppelter wechselrichter
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Replacing the Datamanager card

Preparatory work

1
2
3
4
5
6
Replacing the Da-
Removing the Datamanager card:
tamanager card
Inserting the Datamanager card:
1
2
3
4

And finally...

1
2
3
4
5
WARNING! An electric shock can be fatal.
Follow the five safety rules.
Set the DC disconnector to OFF
Disconnect the AC supply
Remove the DATCOM cover
Disconnect the data communication cables if necessary
Release the device from the wall bracket and remove.
Remove the power stage set cover
(1)
(2)
Connect a new Datamanager card to the RECERBO PC board
Secure the Datamanager card using one TX20 screw (3)
4 x 8 mm ... Datamanager card
, 4 x 9 mm ... Datamanager Card 2.0
Tightening torque = 1.2 Nm
Connect the socket board (2)
, 12-pin ... Datamanager card
, 16-pin ... Datamanager card 2.0
Only for Datamanager cards with WLAN:
fit the antenna (1) using a 7 mm flat spanner
Tightening torque = 0.6 Nm
Fit the power stage set cover
Place the device in the wall bracket and screw in place
Connect the data communication cables if necessary
Fit the DATCOM cover
Restore the AC supply
Only for Datamanager cards with
1
WLAN:
(3)
remove the antenna (1) using a 7 mm
flat spanner
Remove the socket board (2)
2
, 12-pin ... Datamanager card
, 16-pin ... Datamanager card 2.0
Remove the 4 x 8 mm TX20 screw (3)
3
Datamanager card
, 4 x 9 mm ... Datamanager card 2.0
Unplug the Datamanager card from the
4
RECERBO PC board and remove it
129