8.1
Solution
Wrong password
A valid password has to be entered in order to navigate to the menu point Parameters or
Maintenance. Please inform yourself from the persons responsible for the device about your au-
thorisation level and the valid code.
Wrong Fitting
This error message appears if the fitting parameters taken from the fitting code do not match the
actually measured values. Please check whether the scanned in code matches the fitting.
Corrupt Fitting Code
The scanned in fitting code could not be decoded. Please check the code for damage or dirt.
No Fitting Detected
A welding sequence was attempted without a plugged in fitting. Please check the contacts of the
fitting and plug for damage or dirt.
Fitting Shortcircuit Detected
A short circuit was detected on the fitting. Please check the contacts of the fitting and plug for
damage or dirt.
Fitting diameter > 400 mm
The ROFUSE 400 Turbo can only weld fittings of up to 400 mm in diameter.
Dataloss at Start - Memory Full!!
If a welding sequence is started despite this message data loss will occur. The welding is NOT
documented. Back up all data using a USB stick and erase ALL logs.
An impermissible ambient temperature
The ambient temperature is outside the permissible range. Place the device in the shadow or
switch on the heater.
Undervoltage
Turn up the voltage during generator operation.
Overvoltage
Turn down the voltage during generator operation.
Frequency error
The frequency of the supply voltage is outside the permissible range.
A system error
Send in the device immediately for repair. Do not perform any more welding!
Interruption
Interruption of the welding voltage occurred during welding.
The welding voltage is faulty
The welding voltage moved outside the permissible range during welding.
9
The read out and management programme RODATA 2.0
The read out software as well as the installation and operating manual for the software can be
found on the USB stick supplied. The software can also be downloaded if necessary from the
homepage www.rothenberger.com.
10
Maintenance
According to DVS 2208 Part 1, repeat checking (maintenance) should be undertaken at least
once a year.
11
Accessories
You can find suitable accessories in the main catalog or at www.rothenberger.com