Max. permissible pressure
(p
)
max
Max. inlet pressure (p
in;max
Max. inlet temperature
(T
)
in;max
Rated flow rate (Q)
Max. rated flow rate (Q
Max. suction height
Sound pressure level (L
Sound power level (L
WA
– Measured
– Guaranteed
Vibration (a
)
h
This device is intended to be operated using
a mains supply network with a system imped-
ance Z
on the transfer point (house connec-
max
tion) of max. 0.297 Ohm. The user must ensure
that the device is only operated using a mains
supply network that meets the requirements. If
necessary, local power supply companies can
be consulted with regards to the system imped-
ance.
The values for noise and vibration were determ-
ined according to EN 60335-2-79:2012.
The specified total vibration value and the
stated noise emission value have been meas-
ured according to a standardised test method
and can be used to compare one power tool
with another. The specified total vibration value
and the stated specified noise emission value
can also be used for a provisional assessment
of the load.
 WARNING! The vibration and noise emis-
sions may deviate from the specified values
during actual use of the power tool, depend-
ing on how the power tool is being used. Try to
keep the exposure to vibrations as low as pos-
sible. An example of a measure to reduce vi-
bration exposure is limiting the working hours.
All parts of the operating cycle have to be con-
sidered while doing so (for example, times
when the power tool is switched off and times
18 MPa
)
0.8 MPa
40 °C
540 l/h
(9 l/min)
)
max
600 l/h (10 l/min)
0.5 m
)
78.0 dB(A);
pA
K
=3 dB
pA
)
93.1 dB(A);
K
=2.19 dB
WA
98 dB(A)
≤2,50 m/s²
when it is switched on but running without any
load).
Safety information
This section deals with the basic safety instruc-
tions for using the device.
Meaning of the safety
information
 DANGER! If you do not observe this
safety instruction, an accident will occur. The
result of which is severe bodily injury or death.
 WARNING! If you do not observe this
safety instruction, an accident may occur. The
result of which is likely severe bodily injury or
death.
 CAUTION! If you do not observe this
safety instruction, an accident will occur. The
result of which is likely minor or moderate bod-
ily injury.
NOTICE! If you do not observe this safety in-
struction, an accident will occur. The result of
which is possible damage to property.
Pictograms and symbols
Symbols on the device
Caution!
Read the instruction manual carefully.
Familiarise yourself with the controls
and how to use the device correctly.
Caution! If the cable gets damaged
during use, it must be disconnected
from the supply network immediately.
This also includes connecting to the
water supply or trying to eliminate
leaks.
The device is not suitable for connect-
ing to a drinking water supply system.
Electrical devices must not be disposed
of with domestic waste.
Sound power level L
98
dB(A).