Ambient conditions:
Storage temperature:
Ambient temperature:
Humidity:
Minimum temperature stability
of the connecting lines:
Heating system, light, stove, bench lines: at least
150° C temperature-resistant.
Mains lines at least 90° C.
Maximum length of lines:
Stove sensor F I:
Bench sensor(s) F II / FTS II:
Control:
Switching voltage / three-phase 3N:
Frequency:
Switching capacity / Heating AC 1:
Switched current each phase / Heating AC 1: 16 A
Switching capacity / steam generator AC 1: 3,5 kW
Switching capacity / steam generator AC 1: 16 A
Nominal voltage:
Degree of protection (splash-proof):
Connection to the mains is hardwired (fixed connec-
tion).
Additional power units:
S2-18: Boost in switching capacity
from 10.5 kW to 18 kW total capacity;
S2-30: Boost in switching capacity
from 10.5 kW to 30 kW total capacity.
Light:
AC1 switched current:
Fan:
AC1 switched current:
56

Technical data

-25° C to + 70° C
-10° C to + 40° C
max. 95%
50 m
50 m
400 V
50/60 Hz
3x3.5 kW
230 V
IP 24
2 A
230 V, 1 A
Thermal safety:
Stove sensor with overtemperature fuse,
shut-down temperature 139° C.
Automatic shut-down after a max. of 6 hours (with non-
commercial facilities).
Dual sensor system with temperature controls via stove
and bench.
Ranges of adjustment:
Sauna operation:
Climate operation:
Steam generator:
Fan:
Start-time:
Max. start-time:
Max. heating duration to be set: 6 hours *
* If used in apartment buildings, hotels, or similar es-
tablishments, the operational timeframe has to be li-
mited to 12 hours.
Issued: 09-2007
10-110 degrees Celsius at
bench sensor FII
10-80 degrees Celsius at
bench
10% - 80% relative humidity
00% - 100% fan capacity
in 1 minute increments
23 hours 59 minutes
Ident. no. 152 55 22