Climate operation
9
Automatic
9.5
Setting the fan [0 - 100% = P]
0 = off / 100 = max.
Note - If no fan was installed:
select the setting 0 P = OFF
1. Press UP/DOWN buttons 8 until the LED VENT
C lights up:
The display 6 indicates:
-
6O P
or the value set previously.
2. Press PROG/OK 9:
-
The display 6 flashes:
6O P
or the value set previously.
3. Use the UP/DOWN buttons 8 to enter the desired
value, e. g. [50%]:
The display 6 flashes:
-
50 P
4. Press PROG/OK 9:
The display 6 indicates the set value for the fan:
-
50 P
-
The change in fan speed has been set.
52
Operating instructions for the user 9
Continued
Climate operation
9
Automatic
9.6
Setting the relative humidity
1. Press UP/DOWN buttons 8 until the LED CLI-
MATE B lights up:
-
The display 6 indicates the current cabin humi-
dity, e.g. [15 H]:
15 H
2. Press PROG/OK 9:
-
The display 6 flashes:
5O H
-
or the value set previously.
3. Use the UP/DOWN buttons 8 to enter the desired
value (min. 10%; max. 80%) e. g. [50%]:
-
The display 6 flashes:
50 H
4. Press PROG/OK 9:
-
The display 6 indicates the typical cabin humi-
dity, e.g. [15 H] :
15 H
-
The new target value for the relative humidity has
been set.
Note - The beep
If you hear a beep after you have entered the tem-
perature and if the LED TEMP D lights up, ple-
ase observe the following:
Temperature D and relative humidity B are in-
terdependent functions. In compliance with safe-
ty regulations, the beep is a warning to let you
know that the device will automatically select the
max. possible value for the interdependent func-
tions of temperature and rel. humidity.