Installation instructions for trained electricians only
4
Installing the stove sensor FI
with overtemperature fuse
Figures 4 7
Install the stove sensor with overtemperature fuse in
the sauna cabin about 15 cm below the ceiling and
above the heating system, or in accordance with the
cabin manufacturer's specifications.
Use only the supplied 150° C temperature-resistant
connecting line or an equivalent temperature-resistant
line to connect the stove sensor with overtemperature
fuse.
On the outside of the sauna cabin, the temperature-
resistant connecting line can be extended with conven-
tional lines.
WARNING - Electric shock:
Run the power cables separate to other sen-
sor and control lines.
Protect single insulated lines with a pipe
(double insulation).
1. Run four-pin line 5 to mounting location of sto-
ve sensor 4 in the cabin wall and fix in position
with wiring clips.
2. Separate two half shells 1 of stove sensor 4
and connect four terminals of the temperature-re-
sistant line according to the circuit diagram 7
(observe the color coding on the sensors which
correspond to the figures).
3. Insert round adapter plate 2 with the connections
crosswise in half shells 1, close half shells 1
and fix with the two 9 mm long Philips head screws
3.
Check for secure fit of stove sensor 4.
4. Conduct tests according to the chapter "Tests".
5. Bolt stove sensor 4 to the cabin wall in alignment
with the heater, keep a distance of 15 cm to the
ceiling, or install in accordance with the cabin
manufacturer's specifications, using two wood
screws 6.
5
Variant 1
Install bench sensor FII
Figures 5 7
Install the bench sensor in the sauna cabin about 15
cm below the ceiling and opposite of the heating sys-
tem.
The bench sensor with its overtemperature fuse may
only be connected with the supplied 150° C tempera-
ture-resistant connecting line or an equivalent tempe-
rature-resistant line.
On the outside of the sauna cabin, the temperature-
resistant connecting line can be extended with custo-
mary lines.
WARNING - Electric shock:
Run the power cables separate to other sen-
sor and control lines.
Protect single insulated lines with a pipe
(double insulation).
1. Run line 5 to mounting location of bench sensor
4 in the cabin wall and fix in position with wiring
clips.
2. Separate two half shells 1 of bench sensor 4
and connect two terminals of the up to 150° C
temperature-resistant line according to circuit dia-
gram 7.
3. Insert round adapter plate 2 with the connections
crosswise in half shells 1, close half shells 1
and fix with the two 9 mm long Philips head screws
3.
Check for secure fit of bench sensor 4.
4. Conduct tests according to the chapter "Tests".
5
Fix bench sensor 4 to the cabin wall opposite of
the heating system with two wood screws 6
keeping a distance of 15 cm to the ceiling.