Herunterladen Inhalt Inhalt Diese Seite drucken

Fronius Robacta Twin Compact Bedienungsanleitung Seite 35

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Poor wirefeed
Cause:
Braking force set too high
Remedy:
Set the brake to a looser setting
Cause:
Hole in contact tube is dislocated
Remedy:
Exchange the contact tube
Cause:
The wire feed inner liner is defective
Remedy:
Check the wire fee inner liner for kinks, dirt etc.
Cause:
The wirefeed rollers are not suitable for the wire electrode being used
Remedy:
Use suitable wirefeed rollers
Cause:
The wirefeed rollers are exerting the wrong contact pressure
Remedy:
Optimise the contact pressure
Cause:
The wirefeed rollers are soiled or damaged
Remedy:
Clean the wirefeed rollers, or exchange them for new ones
Cause:
Inner liner dislocated or kinked
Remedy:
Exchange the inner liner
Cause:
The inner liner or wire inlet nozzle are of the wrong dimension
Remedy:
Ensure that the inner liner or wire inlet nozzle are correctly dimensio-
ned
Cause:
The inner liner was kinked while being inserted
Remedy:
When inserting the inner liner, only touch and hold it near the infeed
tube
Cause:
After being cut to length, the inner liner is too short
Remedy:
Exchange the inner liner and shorten it to the correct length
Cause:
The wire is being abraded due to excessive contact pressure on the
wirefeed rollers
Remedy:
Reduce the contact pressure on the wirefeed rollers
Cause:
Welding wire is dirty / slightly rusty
Remedy:
Use only high-quality wires that are free of contaminants