Poor welding properties
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
34
Wrong wire alloy and/or wrong wire diameter
Check the wire spool that has been inserted; check the weldability of
the base metal
The shielding gas is not suitable for this wire alloy
Use the correct shielding gas
Unfavourable welding conditions: Shielding gas is contaminated (by
moisture, air), inadequate gas shielding (weld-pool "boiling", drau-
ghts), contaminants in the workpiece (rust, paint, grease)
Optimise the welding conditions
Welding spatter in the gas nozzle
Remove the welding spatter
Turbulence caused by too high a rate of shielding-gas flow
Reduce the shielding-gas flow-rate. Recommendation:
Shielding-gas flow-rate (l/min) = wire diameter (mm) x 10
(e.g. 16 l/min for a 1.6 mm wire)
Too large a distance between the torch and the workpiece.
Reduce the distance between the torch and the workpiece (recom-
mended: 10-15 mm)
Tilt angle of the welding torch is too large
Reduce the tilt angle of the welding torch
Wrong diameter of wirefeed components
Use wirefeed components of the correct diameter

Werbung