Please observe the corresponding operating instruc-
tions. Take care of your equipment with care. Keep
your tools sharp and clean so that you can work well
and safely.
Follow the maintenance instructions and the instruc-
tions for tool changes.
Service information
With this product, it is necessary to note that the fol-
lowing parts are subject to natural or usage-related
wear, or that the following parts are required as con-
sumables.
Wearing parts*: Saw chain, guide rail, chain oil, car-
bon brushes, claw stop
* may not be included in the scope of delivery!
Spare parts and accessories can be obtained from
our Service Centre. To do this, scan the QR code on
the front page.
13. Storage
Store the product and its accessories in a dark, dry
and frost-free place that is inaccessible to children.
The optimum storage temperature lies between 5°C
and 30 ˚C.
Store the product in its original packaging.
Cover the product to protect it from dust or moisture.
Store the operating manual with the product.
• Secure the chain guard before every transport and
storage.
• Store the device in a dry place and out of reach of
children.
• When the device is not in use, store it in such a
way that it cannot be activated by an unauthorised
person.
Warning!
Do not store the device unprotected outside or in a
damp environment.
Stow the device using the suspension (Fig. N)
The device has a hanging groove (K).
• Screw a screw to your desired storage location.
• Ensure that the screw has been fitted tightly and
properly.
• Now hang the electric chainsaw with the chain
guard on using the suspension groove (K) on the
screw.
• Make sure that the screw slips neatly into the
groove.
42 | GB
14. Electrical connection
The electrical motor installed is connected and ready
for operation. The connection complies with the ap-
plicable VDE and DIN provisions. If it is necessary
to replace the connection cable, this must be done
by the manufacturer or their representative to avoid
safety hazards. The customer's mains connection as
well as the extension cable used must also comply
with these regulations.
• The product fulfils the requirements of EN 61000-
3-11 and is subject to special connection require-
ments. This means that use at any freely selectable
connection points is not permitted.
• Given unfavourable conditions in the power sup-
ply the product can cause the voltage to fluctuate
temporarily.
• The product is only intended for use at connection
points that
a) do not exceed a maximum permissible mains
impedance "Z" (Zmax. = 0.294 Ω), or
b) have a mains constant current carrying capacity
of at least 100 A per phase.
• As the user, you are required to ensure, in consul-
tation with your electric power company if neces-
sary, that the connection point at which you wish to
operate the product meets one of the two require-
ments, a) or b), named above.
Important information
In the event of overloading, the motor will switch itself
off. After a cool-down period (time varies) the motor
can be switched back on again.
Damaged electrical connection cable
The insulation on electrical connection cables is of-
ten damaged.
This may have the following causes:
• Pressure points, where connection cables are
passed through windows or doors.
• Kinks where the connection cable has been im-
properly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the
wall outlet.
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insula-
tion damage.
Check the electrical connection cables for damage
regularly. Ensure that the connection cables are dis-
connected from electrical power when checking for
damage.
Electrical connection cables must comply with the
applicable VDE and DIN provisions.
www.scheppach.com