FIXING THE SANICUBIC UNIT TO THE FLOOR
8h
The SANICUBIC
®
Pro unit is equipped with fittings to hold it on
the floor and
prevent it from turning or moving.
1- Place the unit on the desired spot.
2- Draw the outline of the unit.
3- Position the brackets and fix them to the floor as shown on
the template diagram (
8h
4- Put the unit back in place.
5- Fix the unit in place with the screws.
ELECTRICAL CONNECTIONS
8i
1- The electrical installation work must be carried out by a
qualified electrician.
The electrical installation must comply with the standards in
force in the country concerned
1- The power supply must be of the class 1 type. The unit must
be connected via an earthed connection box. The electric
power circuit must be protected by a high-sensitivity 30 mA
differential circuit breaker set at 20 A. The connection must be
used solely to power the SANICUBIC
on the unit is damaged, it must be replaced by the manufactu-
rer or its after-sales service to avoid all danger.
9
ALARM OPERATION
1/ General alarms:
High level alarm:
If the water level in the unit is abnormally high: the buzzer is
triggered and the red LED comes on; the other motor starts
up 3 seconds later (see the illustration showing the control
keyboard).
Temporary alarm:
If one of the 2 motors runs for more than 1 minute: the buzzer is
triggered and the red alarm LED comes on; the other motor starts
up 3 seconds later.
Mains power supply alarm:
In the event of a mains power failure (or if the unit is
unplugged): the buzzer is triggered and the red alarm LED
comes on; the yellow mains power LED also flashes.
2/ Resetting the general alarms:
If the problem that has triggered one of the alarms referred to
above ceases, the buzzer stops, but the red alarm LED stays
on to memorize the fact that the system has met with a
problem.
The "Reset alarm" key on the keyboard is used to switch the
buzzer off in all cases, but it only switches the red LED off if
the problem that triggered the alarm has been dealt with. The
alarm lights on the remote control box also stay on until the
problem has been dealt with. This avoids the risk of having a
system "abandoned" in fault status.
3/ Resetting the general alarms:
The electronic system measures the current input
motor and enables detection of 2 types of fault:
-
a <
minimum threshold, which can be due to: a fault in
I
I
the motor power supply (short-circuit), a capacitor fault,
disconnected internal pipes (eg.through blockage) (turbine /
macerator system).
-
I
a >
I
maximum threshold, because the macerator system is
blocked.
Both of these cases lead to the following results: the motor in
fault status stops, the corresponding red LED comes on, the
alarm is triggered, and the second motor is started.
If the power consumption of the second motor is also outside
the limits: that motor also stops, and the corresponding red
LED comes on.
).
1
®
Pro. If the power lead
(I a)
The buzzer can be stopped by pressing the "Reset alarm" key, but
the red motor LED stays on. When the "override" key for the corres-
ponding motor is pressed, the green LED comes on if the fault is no
longer present. Until the "override" key for the motor is pressed, the
unit continues to operate on one motor. The "override" key is used
to reinitialize the program. The unit then attempts to operate using
both motors (alternately).
UNIT ALARM
motor 1
LED
"Override"
REMOTE ALARM MODULE
red
motor 1
alarm
LED
The remote alarm module is connected to the SANICUBIC
Pro via an HF link. It receives the various types of alarm
information from the unit. If other HF appliances interfere with
the system, a switching system is fitted for the HF code lin-
king the base board with the remote alarm module.
The code can be changed using the switches located on the
2 boards.
In the event of interference with
other HF equipment or other
SANICUBIC
®
nearby, unplug the unit
and the remote module,
flip one of the 4 switches (or several
swithces) on the unit board,
to each
and do the same on the remote unit
board.
WARNING:
You should have the same
code on the unit board and on the
remote alarm board.
To install the module on a wall, see illustration:
"General
motor 2
"Mains"
alarm"
LED
LED
LED
motor 1
motor 2
"RESET"
"Override"
General
alarm
red
red
motor 2
general
transmission
alarm
alarm
LED
LED
Pro units installed
yellow
green
mains
alarm
alarm
LED
LED
®