Herunterladen Diese Seite drucken

Parkside PHDP 180 C2 Originalbetriebsanleitung Seite 34

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 5
GB
MT
Pressure setting (20)
The trigger gun pipe can be turned
through three levels.
• ⭯ low pressure
• ⭮ high pressure
• LC display (15)
The display shows the set pressure
when the switch lever is pulled.
high pressure for walls and
foam
medium pressure for vehicles
low pressure for sensitive ob-
jects
Bow-type handle (2)
With the bow-type handle pulled out, you
can conveniently roll the device.
• Pulling out the handle:
Pull the bow-type handle up.
• Pulling in the handle:
Press the release (3) on the bow-type
handle and pull the bow-type handle
down.
Inserting the batteries
Insert the batteries in the battery compart-
ment before using the device for the first
time.
Tools required
• Phillips screwdriver (not included)
Procedure
1. Remove the screw from the battery
compartment cover (16).
Remove the cover of the battery com-
2.
partment.
Insert the batteries (35) in the battery
3.
compartment. Pay attention to the cor-
rect polarity when inserting the batter-
ies in the battery compartment.
Press the switch lever (17) on the trig-
4.
ger gun (1).
34
The LC display shows the selected pres-
sure. If the LC display is not displaying
anything, check the direction of the bat-
teries.
Insert the cover of the battery compart-
5.
ment.
6. Fasten the cover of the battery com-
partment using the screw.
Setting up the device
1. Place the device horizontally on a level
surface.
Insert the high-pressure hose through
2.
the guide for the high-pressure hose
(9).
3. Insert the high-pressure hose into the
high-pressure connection on the trigger
gun (1).
Do not guide the hose through the
bow-type handle (2) as to not obstruct
the bow-type handle.
Establishing a water supply
You have two options to supply the device
with water:
• Household water connection
• Suctioning standing, clean water, e.g.
rain barrel
Household water connection
Requirements
• Supply hose: Garden hose with fitted
garden hose adaptor (34); ⌀ 13 mm
(½"); length between 5 m and 30 m
Minimum pump capacity: 540 l/h
(9 l/min)
• System separator
A system separator (check valve)
prevents the backflow of water and
cleaning agent into the drinking water
pipeline.
• According to current regulations, a
pressure washer must never be con-
nected to the drinking water network

Werbung

loading