MT
Roll the high-pressure hose around the
4.
hose reel (5).
Troubleshooting
The following table will assist you in fixing faults:
Problem
Device does not work
Device does not convey wa-
ter
No pressure in device
Water system leaky
40
5. Store the mains connection cable in the
Possible cause
On/Off switch (32) turned
off
No mains power supply
Incorrect voltage supply
Air locks in the pressure
washer
Air locks in the pressure
washer
Pressure loss in line
Connections not correctly in-
stalled
Water connection (28) leaky Turn off the device and dis-
holder (11) provided.
Error correction
Check the position of the
On/Off switch
Check the socket, mains con-
nection cable, plug and fuse
and have them repaired by a
qualified electrician if neces-
sary.
Check whether the electrical
system matches the informa-
tion on the type plate
Turn the device on and press
the switch lever (17).
Bleeding, p. 38
Bleeding, p. 38
Check the water supply
Turn off the device and dis-
connect it from the mains. Re-
connect the device to the wa-
ter supply (see Establishing a
water supply, p. 34)
connect it from the mains.
Change the quick connect-
or for the garden hose (29)
including sealing ring (see
Spare parts and accessor-
ies, p. 43)