14. Troubleshooting
The following table shows fault symptoms and describes remedial measures in the event of your machine failing to
work properly. If you cannot localise and rectify the problem with this, please contact your service workshop.
Fault
Engine cannot be
started
Generator has
insufficient or no
voltage
15. Maintenance plan
Always comply with the following maintenance intervals in order to ensure problem-free operation.
ATTENTION! At initial start-up, engine oil and fuel must be filled.
every use
Checking the
engine oil
Changing the
engine oil
Checking the air
filter
Cleaning the air
filter
Visual inspection of
the device
Cleaning the spark
plug
Check and readjust
the throttle valve
Cleaning the
cylinder head
Adjust the valve
play
Attention: Only have points "X*" carried out by an authorised specialist company.
36 | GB
Possible cause
Automatic oil cut­off trips
Spark plug sooty
No fuel
Electronics defective
Overload protection switch
tripped
Air filter dirty
Before
after operating for 20
hours
X
first time, then every
50 hours
X
X
www.scheppach.com
Remedy
Check oil level, fill with engine oil
Clean or replace spark plug
Top up with fuel
Repair by an authorised service centre.
Restart the power generator, reduce consumers
Clean or replace filter
after operating for 50
hours
X
X
Gap: 0.6 - 0.7 mm,
replace if necessary
after operating for 300
hours
Change filter insert if
necessary
X*
X*
X*

Werbung