Herunterladen Diese Seite drucken

Toro Tempus Pro Controller 4 Bedienungsanleitung Seite 6

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 130
Tempus Pro Controller 4-8-12-16
Back Module Components
1. Terminal block.
2. DB15 Connector to the Control Module.
3. Connector for the Tempus Pro 4-Station Module.
4. Mounting holes for wall installation.
5. Jumper to be connected only if Sensor is Normally Closed type and no
Sensor is used.
6. Conduit knockout.
4
2
1
3
3
4
6
6
5
4
6
6
4
Back Module Installation
1. For safe, reliable operation, select an installation site which can ideally provide
the following conditions:
• Inside a garage or other structure which will provide protection from the weather.
• Access an AC power souce (within 4' [1.2 m]) which is not controlled by a light
switch or utilized by a high current load appliance, such as a refrigerator or air
conditioner.
• Access to the s prinkler control valve wiring and optional accessory wiring.
2. Position the Controller Back Module on the wall at eye level and drive a first wood
screw through a top opening (A). Position the Back Module horizontally and drive
a second wood screw through the diagonally opposite opening (B). See Figure 1.
Then drive two more wood screw through the two remaining openings (A) and B).
Note: If installing the controller on drywall or masonry, install screw anchors.
3
Install the lower screw anchor XX" (XXmm) directly below the top screw anchor.
Note: Conduit and adapters are not provided. Install conduit as required by local
3
electrical codes.
3. Remove the conduit
knockout.
Install 1/2" (13 mm) conduit
(C) for 24Vac power wires
and for valve wires.
Figure 1
B
B
A
A
C
C
C

Werbung