Herunterladen Diese Seite drucken

Toro Tempus Pro Controller 4 Bedienungsanleitung Seite 20

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 130
Tempus Pro Controller 4-8-12-16
Note: It is possible to select only 1 single Program, A, B C or D, or ALL Programs.
Note: water flow is not tested for Overflow, Underflow and Loss when:
• 24Vac is missing
• Control Panel is removed from its Back Module
• A Valve is activated Manually
• An Hydraulic Test is running
• Tempus Pro is in Pause/Rain
• The condition for testing Overflow, Underflow and Loss ends before the period
needed for calculating Overflow, Underflow and Loss.
20
Local Action on Sensor
or a Meter Function ACTIVE
→ No action
NONE
→Start the Program(s) selected in settings
START
→ Stop the Program(s) selected in settings
STOP
→ Skip to the next programmed station for the Program(s)
SKIP
selected in settings
→ Put on HOLD the Program(s) selected in settings
HOLD
If enabled, MV remains open
→ Put on RAIN the Program(s) selected in settings.
RAIN
Available Local Actions for each function:
Local Actions
When Sensor
When Meter
becomes active
Overlfow is Active
NONE
Yes
START
Yes
STOP
Yes
SKIP
Yes
HOLD
Yes
RAIN
Yes
REMOVE
Automatic when Sensor
HOLD
becomes normal again
REMOVE
Automatic when Sensor
RAIN
becomes normal again
When Meter
When Meter
Underflow is Active
Loss is Active
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes
No
No
No
No
No
No
No
No
No
No
No
No
No