Note: UNDR-ACTN page is available only if UNDR P/m is not set to OFF.
Setting the Meter Loss Function.
Meter Loss status is Normal if during Loss calculation the number of pulses during
the Loss Period is below the set Pulses/Loss Period Threshold.
Meter Loss status is Active if during Loss calculation the number of pulses during the
Loss Period is above the set Pulses/Loss Period Threshold.
Setting Loss Threshold.
• Press the
button to access the Controller's Settings.
• Press the
or
buttons to select LOSS PULSE.
• Press the
or
button to select one of the Loss threshold:
Off → 0001 . . → . . 9999 Pulses (pulses per Loss Time).
Note: selecting OFF the following 3 settings are not visualized.
Setting Meter Loss Time.
• Press the
button to access the Controller's Settings.
• Press the
or
buttons to select LOSS-TIME.
• Press the
or
button to set a Loss Period:
1m. . → . .8h, increment in minutes.
Note: LOSS-TIME page is available only if LOSS PULSE is not set to OFF.
Setting the Program(s) on Loss Active.
• Press the
button to access the Controller's Settings.
24
• Press the
or
buttons to select LOSS @ PRG.
• Press the
or
button to select ALL 4 Programs (A, B, C, D) or ONLY one of
them:
Program A, or
Program B, or
Program C, or
Program D, or
ALL.
Note: LOSS @ PRG page is available only if LOSS PULSE is not set to OFF.
Setting Local Action on Loss Active.
• Press the
button to access the Controller's Settings.
• Press the
or
buttons to select LOSS-ACTN.
• Press the
or
button to select one of the following Actions:
NONE → No action
START → Start the Program(s) selected in the LOSS @ PRG page.
Note: LOSS-ACTN page is available only if LOSS PULSE is not set to OFF.
Meter Read (available only with WiFi option installed and connected to Internet).
With the WiFi option installed and connected to Internet the current water usage
value can be periodically sent to the APP.
Setting Water Usage Read.
• Press the
button to access the Controller's Settings.
• Press the
or
buttons to select METER READ.
• Press the
or
button to disable the Meter Read function or to select a
period of time for reading the meter periodically:
Off → 15m . . → . . 24h (15 minute increment).