10.

TROUBLESHOOTING

Error
Water is not dispensed
Not enough water is
dispensed
Cold water cannot be
dispensed
Cannot dispense CO
2
Cold water not cold
enough
Water contains too little
CO2
When the CO2 button is
pressed, only CO2
escapes
Lighting at the water
outlet flashes
Cause
Not enough water
pressure in the water
supply
Filter cartridge is blocked
Problem with the pressure
regulation or the pump in
the device
Not connected to the
power supply
Filter cartridge is blocked
Incoming water pressure
too low
On/off switch for cooling
(COLD) is off
No coolant available
Problem with the hermostat
or compressor
No water in cold water pipe
Ice formation in the cold
water tank
Not enough water in the
tank
Defective pump
CO2 on/off switch on
the rear panel is
switched off
CO2 pressure is too high
Thermostat is not set
correctly
CO2 gas cylinder is
empty
CO2 tank must be
vented
Pump does not react
Wastewater tank is full
Leakage is detected
Error recovery
Increase the water pressure
Insert new filter
Contact a service technician
Connect the device to the power supply
Insert new filter
Check and, if necessary, increase incoming water
pressure
Switch on the on/off switch for the cooler (COLD)
on the rear panel
Contact a service technician
Contact a service technician
Check the water supply. If it is OK, check the water
pipes in the appliance
Switch off the appliance or disconnect it from the
mains and leave it switched off for approx. 24 hours.
This allows any ice that has formed to melt
Top up the water or refill the tank and check the
device's pipework
Contact a service technician
Switch the CO2 on/off switch to on
Close the pressurised CO2 cylinder and
release the pressure using the pressure
regulator. Press the CO2 selection button and
let the water drain to release the pressure in
the carbonator. Release the CO2 selection
button when no more carbonated water flows
out. Open the pressurised CO2 cylinder again
and set the pressure to 3 bar. Press the
selection button for CO2 water until water
with CO2 flows out.
Check the thermostat, adjustment screw under
the right side-panel, and, if necessary, reduce the
temperature
Replace the CO2 gas cylinder.
Turn off the water and actuate the CO2 outlet
until only gas escapes. Then turn on the water
again and allow the CO2 to refill
Disconnect the device from the power supply for
30 seconds and reconnect and press the CO2 key
again. Make sure that the CO2 function switch is
turned on.
Empty the waste water tank.
Contact service technician