Fault
Unit is not providing water or too low a flow rate.
Dyed flushing water during the start-up.
If the fault cannot be rectified with this troubleshooting guide, our customer service team must be contacted, providing information of the series
and production number (see type label of the unit).
10.1 Service notification
When the litre display begins to flash, it is time
for a service, because 150 regenerations are
433 L
reached.
Please contact customer service.
Motor position error
POS
Please contact customer service.
Error with power monitoring of the magnetic
valves
TBD
Please contact customer service.
Storage error
Para
Please contact customer service.
11 Warranty
If the product malfunctions during the warranty period, contact your
contract partner, the installation company, and quote the unit type and
production number (see technical specifications or the type plate on
the unit).
Non-compliance with the installation conditions and the operator respon-
sibilities leads to the loss of warranty and exclusion of liability.
The wearing parts defined in the "Operator responsibilities" section
and the consequences of failing to replace these parts on time are not
covered by the two-year legal warranty.
28
Cause
Primary pressure too low.
Abrasion particles of the exchanger resin.
Rectification
Increase primary pressure (adjust pressure
reducer if required) and activate manual re-
generation.
Repeat start-up flushing.