SB MB
High-pressure module 608, 608fl
High pressure module 908
Hot water temperature for continuous opera-
tion, all high-pressure modules type 908
Hot water temperature for continuous opera-
6
tion, electrically heated
1
high-pressure module 608 / high-pressure module 608fl / high-pressure module 908
2
for customer warm water supply the fresh water requirement decreases by the corresponding amount
3
Water supply temperature +8°C, floor heating not in operation, burner power 64 kW
4
Water supply temperature +8°C, floor heating not in operation, burner power 40 kW
5
Water supply temperature +8°C, floor heating not in operation, burner power 72 kW (only oil burner)
6
Water supply temperature +8°C, floor heating not in operation, electric heating capacity 24 kW
Base exchanger
Capacity
Water hardness of softened water
Salt tank, CAB
Salt tank, SKID
RO system
Permeate capacity, min. (at 15 °C water tem-
perature), CAB
Permeate capacity, min. (at 15 °C water tem-
perature), SKID
Operating pressure when new, max.
Membrane desalination rate
Water temperature range
Ambient temperature max.
Residual hardness inlet water
Maximum permeate conductivity for stain-free
drying
Buffer tank permeate, CAB/SKID
Miscellaneous
Oil quantity of HP pump
Oil type
Determined values in acc. with EN 60335-2-79
Hand-arm vibration value
High-pressure gun
Spray lance
Uncertainty K
Sound level L
pA
SB MB
High-pressure module 608, 608fl
High pressure module 908
Oil burner
Heating capacity
Fuel consumption of heating oil (11.86kWh/kg) kg/h
Fuel nozzle
Fuel pressure
Temperature difference of exhaust gas-air
Exhaust gas loss with burner capacity below
50 kW (above 50 kW)
Soot index
Fuel
ABS fuel tank heating oil
max. heatable washing stations (each approx.
2
15 m
)
Gas burner
Heating capacity
Fuel consumption of natural gas (9.4 kWh/m
Fuel consumption of liquid gas (25.5 kWh/m
Nominal width of gas supply line
Fuel pressure (gas pressure of supply line),
natural gas *
Fuel pressure (gas pressure of supply line), liq-
uid gas *
Temperature difference of exhaust gas-air
max. heatable washing stations (each approx.
2
15 m
)
76
5/10-2
Piece
2
1
Piece
-
2
°C
about 40
5
°C
53
-
3
°dH/m
220
°dH
0...0.3
l
120
l
120
l/h
200
l/h
200
MPa (bar)
1.4 (14)
%
98...99
°C
2...30
°C
40
°dH
0...0.3
μS/cm
under 100
l
280/700
l
0.7
Hypoid SAE 90 (6.288-016.0)
Uncertainty K
Sound power level L
ty K
WA
2
m/s
<2.5
2
m/s
<2.5
Dimensions SB MB CAB
2
m/s
0.1
Width
dB(A)
65
Depth
5/10-2
Piece
2
1
Piece
-
2
kW
34.5
3.3
0.85/60°
MPa (bar)
1.025 (10.25)
K
170
%
10 (9)
0...1
EL heating oil or diesel
l
60/700
2
kW
34.5
3
3
) m
/h
4.1
3
3
) m
/h
1.5
Inches
3/4
mbar
>22
mbar
>50
°C
approx. 200...230
2
9/12-2
5/10-3
-
3
2
2
-
1
about 32
38
-
300
200
General
dB(A)
3
pA
+ Uncertain-
dB(A)
86
WA
mm
2700
mm
900
Technical data
9/12-2
5/10-3
-
3
2
2
-
1
50
4.5
1.25/60°
40 kW: 1.05 (10.5)
64 kW: 1 (10)
3
50
5.9
2.2
3
English
9/12-3
5/10-4
1
-
4
3
2
3
-
1
about 22
-
300
220
150
120
200
120
400
300
Height
Net weight, max. (with 30 kg pack-
aging)
Maximum weight
9/12-3
5/10-4
1
-
4
3
2
3
-
1
72
6.9
1.75/60°
1.05 (10.5)
4
max. 67
7.6
2.8
3
9/12-4
2
1
-
2
3
4
300
150
200
400
mm
2100
kg
1100
kg
1750
9/12-4
2
1
-
2
3
4
3