Herunterladen Inhalt Inhalt Diese Seite drucken

Kärcher SB MB Bedienungsanleitung Seite 48

Vorschau ausblenden Andere Handbücher für SB MB:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Standard setting
1. Pull out the dosing amount adjustment knob.
Venting lever
1
Venting button
2
Dosing amount adjustment knob
3
2. Alternately press and release the ventilation button
while turning the adjustment knob to the desired set-
ting.
Washing program
Detergent
High-pressure Wash RM 806
Wet foam (option)
RM 806
Dry foam (option)
RM 812
Hot wax
RM 820
Top care
RM 821
Dirt Loosening (op-
RM 806
tion)
Insects Loosening
RM 803
(option)
Power foam
RM 838
Power rim foam
RM 802
Power wax
RM 820
3. Release the ventilation button.
4. Press in the dosing amount adjustment knob
Setting the dry foam station
Output for water/detergent
1
Dosing valve for water/detergent
2
Input for water/detergent
3
Air dosing valve
4
Air output
5
Compressed air pressure gauge
6
Pressure reducer for air
7
Pressure gauge for water
8
Pressure reducer for water
9
Dry foam dosing pump
1
48
Standard setting for water
1. Open the fresh water inlet.
2. Run the wash programme Foam Wash at a washing
station.
3. Set the water pressure reducer to 0.25 MPa (2.5
bar).
Standard setting for water/chemistry
1. Set the dosing pump for dry foam to 20%. For the
procedure, see "Setting the dosing pumps".
2. Open the fresh water inlet.
3. Remove the hose at the output of the water/chemis-
try distribution block and replace it with a piece of
hose approx. 400 mm long (PVC hose 6/4).
4. Run the Foam Wash washing programme for this
washing station.
5. Adjust the fluid flow from the hose section to 300 ml/
min by adjusting the dosing valve for water/deter-
gent (measure with measuring cylinder).
6. End the currently running Foam Wash washing pro-
gramme.
7. Remove the piece of hose and reconnect the hose
to the washing station.
8. Repeat the setting of the dosing valves for water/
chemistry for the remaining washing stations.
Standard setting for air
Adjustment
1. Set the air pressure reducer to 0.25 MPa (2.5 bar).
knob posi-
2. Insert the service tool 6.901-074.0 between the air
tion(%)
output and the hose to the washing station.
50
3. Run the Foam Wash washing programme for this
washing station.
50
4. Adjust the air dosing valve so that the service tool
50
pressure gauge reads 0.15 MPa (1.5 bar).
5. End the currently running Foam Wash washing pro-
50
gramme.
50
6. Remove the service tool and reconnect the hose to
50
the washing station to the air distribution block.
7. Repeat the setting of the air dosing valves for the re-
maining washing stations.
50
Note
After the standard setting has been carried out, the con-
80
sistency of the foam should only be changed by adjust-
80
ing the air dosing valves.
50
Wheel cleaning/Intensive Foam set (option)
1. Pull out the detergent suction hose.
Detergent input
1
Nozzle insert
2
Detergent suction hose
3
2. Select the nozzle insert for the desired mixing ratio:
Nozzle colour
No nozzle
Grey
Black
beige
red
White
Blue
light brown
green
orange
brown
yellow
violet
Pink
* Hydrominder type 515 GB
** Hydrominder type 511 GB
Water/detergent
Wheel
Intensive
cleaning *
Foam **
1:1
4:1
1.2:1
5:1
2:1
6:1
4:1
8:1
6:1
17:1
9:1
23:1
10:1
25:1
13:1
36:1
21:1:
48:1
26:1
64:1
30:1
75:1
38:1
90:1
50:1
120:1
100:1
240:1
English
Standard setting for water/chemistry
Wheel cleaning
Detergent
RM 801
RM 802
Nozzle colour
Blue
yellow
Mixing ratio
10:1
38:1
1. Insert the nozzle insert into the detergent inlet as far
as it will go.
2. Fit the suction hose.
3. Adjust the pressure at the adjustment screw:
Adjustment screw
1
Wheel cleaning
Intensive Foam
0.55...0.65 MPa
0.8...0.85 MPa
(5.5...6.5 bar)
(8.0...8.5 bar)
Standard setting for air
1. Set the air pressure reducer:
Wheel cleaning
Intensive Foam
0.25...0.3 MPa
0.3 MPa
(2.5...3 bar)
(3 bar)
ATTENTION
Risk of damage
Acidic detergents can damage the system.
Only use alkaline detergents to clean the wheels.
Note
After the standard setting has been carried out, the
spray pattern should only be changed by adjusting the
air pressure reducer.
Even application of wheel cleaner is improved if a suita-
ble dye is added to the wheel cleaning concentrate.
Micro Emulsion Set (option)
1. Set the pressure as required by turning the adjust-
ment screw.
Adjustment screw
1
Setting the base exchanger WAT-S 202
(option)
The current time must be set at the control head of the
base exchanger in order that regeneration is carried out
at night.
1. Pull out the adjustment knob and turn it until the cur-
rent time is displayed.
Adjustment knob
1
Window with pointer
2
Intensive
Foam
RM 838
yellow
90:1

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis