Message displays
Message category display:
1
red: critical error. Depending on the error, the sys-
tem reacts as follows:
The system goes into emergency operation.
One or more washing stations are locked out.
The entire system is locked out.
Yellow: Fault; the system can continue operating
green: Event; information for the operator
Error description
2
Note
Only faults that can be rectified by the operator are list-
ed here.
Error number
Cause
F0103
Malfunction oil separator / recycling
F0105
Motor circuit breaker of high-pressure pumps has tripped
F0107
Air pressure switch signals no pressure
F0113
Motor circuit breaker / automatic circuit breaker frost protection
F0114
Hot water temperature too low
F0115
Motor circuit breaker of foam hose heater
F0116
Motor circuit breaker of stations
F00170
HP pump 1 overcurrent
F00174
HP pump winding protect.contact 1
F00176
HP pump 1 oil level too low
F0191
Coin signal remote control 1
F0210
HP pump 2 overcurrent
F0214
HP pump winding protect.contact 2
F0216
HP pump 2 oil level too low
F0231
Coin signal remote control 2
F0250
HP pump 3 overcurrent
F0254
HP pump winding protect.contact 3
F0256
HP pump 3 oil level too low
F0271
Coin signal remote control 3
F0290
HP pump 4 overcurrent
F0294
HP pump winding protect.contact 4
F0296
HP pump 4 oil level too low
F0311
Coin signal remote control 4
F0570
Hot water shortage
F0571
Hot water overtemperature
F0574
Oil stoker malfunction
F0575
Exh. gas thermostat triggered
F0576
No flow detected by flow monitor
F0577
Flow monitor is defective
F0578
Automatic hot water circuit-breaker
F5081
Hot water circ. pump motor circuit breaker
F0584
Washing station heater circ. pump motor circuit breaker
F0586
On-site heating
F0587
Water temperature above 60 °C.
F0610
Softener bottle regeneration has failed.
F0612
Osmosis tank running dry
F0613
Osmosis tank level switch
70
Information on the possible cause and correction of
3
the error.
Display of error number and date and time when the
error occurred.
Button to acknowledge the error.
4
Note
If the button is greyed out, the error is still present and
cannot be acknowledged.
If the button has a yellow background, the fault has
been rectified and the error can be acknowledged.
Scroll bar to show how long the current message
5
has been displayed already.
Note
The view switches to the next screen automatically after
approx. 2-3 seconds. The progress bar has then fin-
ished.
Current message number/total number of messag-
6
es display.
Buttons to manually scroll forward and backward
7
through the different message views.
Faults indicated by the controller
In case of faults that are not described here: Acknowl-
edge the message. If the fault occurs again, inform Ser-
vice.
English
Example fault display
Example event display
Rectification
Check or empty external oil separator / Check recycling system
Reset motor circuit breaker. If the fault occurs again, inform Service
Check compressor and compressed air lines
Reset motor circuit breaker or automatic circuit breaker. If the fault occurs
again, inform Service
Washing station heater has been turned off, Check hot water generator and
hot water circuit
Reset motor circuit breaker. If the fault occurs again, inform Service
Reset motor circuit breaker. If the fault occurs again, inform Service
Current consumption of HP pump too high Acknowledge fault. If the fault oc-
curs again, inform Service.
Acknowledge the error. If the fault occurs again, inform Service.
Refill oil. Acknowledge malfunction
At mechanical coin acceptor check the microswitch
Current consumption of HP pump too high Acknowledge fault. If the fault oc-
curs again, inform Service.
Acknowledge the error. If the fault occurs again, inform Service.
Refill oil. Acknowledge malfunction
At mechanical coin acceptor check the microswitch
Current consumption of HP pump too high Acknowledge fault. If the fault oc-
curs again, inform Service.
Acknowledge the error. If the fault occurs again, inform Service.
Refill oil. Acknowledge malfunction
At mechanical coin acceptor check the microswitch
Current consumption of HP pump too high Acknowledge fault. If the fault oc-
curs again, inform Service.
Acknowledge the error. If the fault occurs again, inform Service.
Refill oil. Acknowledge malfunction
At mechanical coin acceptor check the microswitch
Check the hot water supply
Acknowledge the error. If the fault occurs again, inform Service.
Press the Reset button on the oil-firing unit
Press the Reset button on the exhaust gas thermostat
Acknowledge the error. If the fault occurs again, inform Service.
Acknowledge the error. If the fault occurs again, inform Service.
Reset automatic circuit-breaker. If the fault occurs again, inform Service
Reset motor circuit breaker. If the fault occurs again, inform Service
Reset motor circuit breaker. If the fault occurs again, inform Service
Check on-site heating system
Water temperature of external hot water supply above 60 °C. Reduce the wa-
ter supply temperature.
Hardness sensor indicates hard water after regeneration. Refill salt, acknowl-
edge fault
Have the tank filled up to the empty osmosis tank level switch (maximum
switch-on delay of 15 minutes)
Empty and full osmosis tank level switches switch simultaneously.. Check lev-
el switch.