Herunterladen Inhalt Inhalt Diese Seite drucken

Specification - GF U3000 V2 Betriebsanleitung

Ultraschall-durchflussmessgerät
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 73

Specification

11
Specification
General
Measurement Method
Flow Range
Accuracy
Repeatability
Response Time
Selectable Flow Units
Selectable Total Volume Units
Total Volume
Menu Languages
Environmental
Operating Temperature
Storage Temperature
Pipe Wall Temperature
Operating Humidity
Suitable Pipe Types
Pipe Materials
Pipe Diameter (OD)
Pipe Wall Thickness
Pipe Lining
Pipe Lining Thickness
Electronics
Power Supply
Power Consumption
66
Ultrasonic transit-time measurement
0.1 m/s to 20 m/s
Pipe ID >75 mm
Pipe ID 13 mm to 75 mm
All pipe ID's
±0.5% of measured value or ±0.02 m/s whichever is the greater
< 500 ms depending on pipe diameter
Velocity
m/sec, ft/sec.
Volume
l/s, l/min, l/h, gal/min, gal/h, USgals/min,
USgals/h, Barrel/h, Barrel/
day, m³/s, m³/min, m³/h.
liter, gallon, US gallons, Barrel, m³
12 digits
EN, DE, FR, RU, SWE, IT, SP, P, NO, DEN (user selectable)
-20 °C to +50 °C
-25 °C to +75 °C
-20 °C to +135 °C
Max. 90% relative humidity @ +50 °C (+122 °F)
PVDF, PP-H, PE, PB, ABS, UPVC, CPVC, construction steel, iron, stainless
steel, copper
13 mm to 2000 mm
1 mm to 75 mm
Applicable pipe linings include Rubber, Glass, Concrete, Epoxy, Steel
0 mm to 25 mm
12 V to 24 V AC/DC, 1A max. or 86 V to 264 V AC (47 Hz to 63 Hz)
Max. 10.5 W
±0.5% to ±3 % of flow reading for flow
rate >0.2 m/s
±3% of flow reading for flow rate >0.2
m/s
±6% of flow reading for flow rate <0.2
m/s
-4 °F to +122 °F
-13 °F to +167 °F
-4 °F to +275 °F
0.5 inch to 78 inch
0.04 inch to 3 inch
0 inch to 1 inch
User Manual

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis