CALIBRATING THE LAMP

WARNING:
Calibration of the lamp may be carried out by qualified personnel only. If you are not
qualified to do this, do not attempt to calibrate a lamp yourself. Consult a qualified
professional instead.
A hot discharge lamp is under high pressure and can therefore spontaneously
explode. Let the spotlight cool for at least 30 minutes before opening it!
When calibrating the lamp, wear protective glasses and protective gloves!
When carrying out any work, make sure that no foreign bodies enter the housing!
In order to maintain the seal of the OTOS B5 moving head according to protection
class IP65, a new seal must be inserted at the corresponding location after calibrating
the lamp. Carefully follow each step in the instructions below.
If the hotspot is not in the centre of the projection of the light beam, it can be calibrated by means
of two adjustment screws.
Example:
1. Fully disconnect the spotlight from the mains (pull out the mains plug)! Make sure that the
spotlight has cooled down completely!
2. Lock the spotlight head to prevent unintentional twisting (pan and tilt locking).
3. Loosen the 4 Allen screws of the rear head cover (see markings), remove the cover from the
spotlight head, release the safety cable of the cover and place it to one side.
4. Loosen the 4 silver-coloured Allen screws that hold the fan unit to the spotlight head (see markings)
and hang them carefully on the safety cable. Ensure that the supply lines are not damaged.