Mounting
4.1

Mounting procedure

Below, we use a weighbridge as an example for the mechanical installation.
We recommend that you proceed as follows:
S Use appropriate lifting gear to lift one face of the weighbridge that has al­
ready been centered.
S Prepare the load introduction parts and mount the part with the rotation stop
dowel pin below and the load introduction part without the dowel pin above.
The lower load introduction part must be aligned such that the dowel pin
points in the direction in which, later on, the cable outlet and the type plate
are to be point, although do not yet finally fix it.
CAUTION
Position of rotation stop dowel pin:
Radially position open side!
S Use a sufficient amount of the grease provided with the load cells to protect
from wear, tear, dirt and corrosion the upper and lower load introduction
parts in the load carrying element, the dowel pin and the rotation stop on
the load cell.