For C16i3 (third generation and predecessors)
Power supply table (when using the HBM interface converter set SC232/422B
with an internal consumption of approx. 70 mA):
Sum
Num
current
ber of
con
load
sump
cells
1)
tion
1
120 mA
2
170 mA
3
220 mA
4
270 mA
6
370 mA
8
470 mA
10
570 mA
12
670 mA
16
870 mA
1)
Incl. HBM interface converter set SC232/422B
Notice
The plug-in power supply unit , included in the scope of delivery for the HBM
interface converter set SC232/422B supplies 15 VDC/530 mA. So it can be
used for operation with max. 8x C16i... load cells.
5.3
Command set C16i...
Please request the separate documentation of our AD104C electronics, if re
quired. Operating instructions are available in German and English language.
C16i
between converter and junction box
Nominal voltage 12 VDC
2
0.14mm
0.25mm
352 m
500 m
176 m
314 m
117 m
210 m
88 m
157 m
59 m
105 m
44 m
79 m
35 m
63 m
29 m
52 m
22 m
39 m
A05516_01_Y00_01 HBM: public
Maximum cable length
Wire cross-section
2
2
0.5mm
0.14mm
500 m
500 m
500 m
296 m
419 m
197 m
314 m
148 m
210 m
100 m
157 m
74 m
126 m
59 m
105 m
49 m
79 m
37 m
Electrical connection
Nominal voltage 15 VDC
2
2
0.25mm
500 m
500 m
352 m
264 m
176 m
132 m
106 m
88 m
66 m
2
0.5mm
500 m
500 m
500 m
500 m
352 m
264 m
211 m
176 m
132 m
21