Herunterladen Inhalt Inhalt Diese Seite drucken

HBM C16i Montageanleitung Seite 16

Vorschau ausblenden Andere Handbücher für C16i:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Mounting
Structurally, this effect can be counteracted by shifting the bearing points on
the weighbridge as far upward as possible, towards the neutral bending axis.
CAUTION
Before loading the bridge for the first time by driving on it with a truck / vehicle,
do in any case adjust the lateral stops such that the load cells' permissible
skewings or lateral displacements of the load introduction parts are not ex­
ceeded (see chapter 8 "Dimensions"). Otherwise, the load cells or load
introduction parts might be damaged.
CAUTION
Adjust lateral stops of
the weighing platform
Notice
Type C16i... load cell is metal‐clad by laser‐welding and made from rustproof
materials. Therefore they comply with protection class IP68 according to EN 60
529 (IEC 529) under the stated test conditions (see chapter 7 "Specifications").
In general, the load cell permit steam jet cleaning. However, the conditions for
max. pressure, temperature, etc., stated in the EN 60 529 for protection class
IP69K, must be observed.
When EPO3/50t, C16/EPU44A or C16/ZOU44A mounting parts from HBM are
used, the integral rotation stop device, described in chapter 4 "Mounting", can
be used. With customized mounting parts, HBM provides drawings showing
the position and mounting of the rotation stop. In this case, special attention
must be paid to the observance of the tolerances stated for the dowel pin posi­
tion, to prevent the load cells from being damaged.
14
A05516_01_Y00_01 HBM: public
C16i

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis