MAINTENANCE

It is advisable to check the system with the pressure regulator for leaks and to ensure that it is
functioning properly occasionally, such as once per year.

REPLACEMENT

If there is any sign of wear or if the product or parts thereof are damaged, it must be replaced.
When the product has been replaced, observe the steps ASSEMBLY, LEAK TESTING and
START-UP.
To ensure that the installation works faultlessly under normal operating conditions, it is
recommended that you replace the device within 10 years of the date of manufacture.
Product damaged due to flooding!
This causes corrosion and malfunctions to the pressure regulator.
Replace the pressure regulator following flooding!

RESTORATION

If the actions described in TROUBLESHOOTING do not lead to a proper restart and if there is
no dimensioning problem, the product must be sent to the manufacturer to be checked. Our
warranty does not apply in cases of unauthorised interference.

SHUT-DOWN

Close the cylinder valve and then the shut-off devices of the consumer unit. When the system
is not used, all valves must be kept closed.

DISPOSAL

To protect the environment, our products may not be disposed of along with
household waste.
The product must be disposed of via a local collection station or a recycling station.

TECHNICAL DATA

Inlet pressure p
Outlet pressure p
d
Nominal flow rate M
Maximum admissible pressure
Ambient temperature
Optional response pressure PRV
Housing material
Refer to the type label of the pressure regulator for more technical data and special
settings!
18 / 64
1 to 16 bar
set: between 0.7 and 2.0 bar.
adjustable:
max. 60 kg/h
g
PS 25 bar
-20 °C to +50 °C
see type label
die-cast zinc ZP0410
Mitteldruckregler Typ VSR 0126
from 0.5 to 2.0 bar (4 bar)
Artikel-Nr. 01 267 50 d