Fault cause
Abnormal flame pattern of
non-adjustable pressure
regulator
In case of continuous gas escaping via the pressure relief valve PRV via the breather the
pressure regulator must be replaced with a new pressure regulator.
In case of gas smells, leaks, gas escaping via the PRV or faults in the consumption
equipment, SHUT DOWN THE SYSTEM immediately. Contact a specialised company.

MAINTENANCE

Upon proper ASSEMBLY and OPERATION, the product is maintenance-free.

REPLACEMENT

If there is any sign of wear or if the product or parts thereof are damaged, it must be
replaced. When the product has been replaced, observe the steps ASSEMBLY, LEAK
TESTING, and START-UP. To ensure that the installation works faultlessly under normal
operating conditions, it is recommended to replace system parts subject to wear or ageing,
e.g. pressure regulators, hose assemblies, shut-off devices, as required:
• Recommendation: replacement times 5 years.
The gasket in the inlet connector (if provided) must be changed every time the cylinder has
been replaced or disassembled. It must also be replaced if it is damaged or the connection is
no longer tight.

RESTORATION

If the actions described in TROUBLESHOOTING do not lead to a proper restart and if there is
no dimensioning problem, the product must be sent to the manufacturer to be checked. Our
warranty does not apply in cases of unauthorised interference.

SHUT-DOWN

Close the gas supply and then the shut-off fittings of the connected consumer equipment.
When the LPG system is not in use, all valves must remain closed.
Close the gas cylinder valve(s) for storage and transport.
The protective cap serves as additional protection against the escape of gas in the event of
leaks.
Mount the protective cap to secure the gas cylinder valve(s) during transport.
Close all free connections in the feed lines of the LPG system tightly with a
suitable cap to prevent gas from flowing out.

DISPOSAL

To protect the environment, our products may not be disposed of along with
household waste.
The product must be disposed of via a local collection station or a recycling station.

WARRANTY

We guarantee that the product will function as intended and will not leak during
the legally specified period. The scope of our warranty is based on Section 8 of
our terms and conditions of delivery and payment.
Artikel-Nr. 02 593 99 a
Action
Compare the nominal outlet pressure of the pressure
regulator with the nominal inlet pressure of the connected
consuming device:
 if they do not correspond, replace the pressure regulator
or the gas appliance.