Herunterladen Inhalt Inhalt Diese Seite drucken

Storage; Information About Recycling And Disposal - Parkside PTPU 1500 A1 Originalbetriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 16
pump wheel. Rotate the pump wheel unit
crack or surface damage on the pump wheel unit
Faults
Pump
does not run
1
Pump
does not pump
1
Insufficient pumping capacity
Pump
switches off after
1
a short time
z Storage
Keep the device clean and dry and out of the reach of children.
Protect the device from frost.
If you are not going to use the pump for a longer period of time, then you must clean the device
thoroughly after the last use and before using it again. Otherwise it may be difficult to start the
device because of deposits or residues.
z Information about recycling and disposal
DON'T THROW AWAY – RECYCLE!
According to European Directive 2012/19/EU, used electrical devices must be collected
separately for environmentally compatible recycling or recovery. Please return this device to an
approved waste management company or use your municipal waste collection service. Please ensure
you comply with local regulations. If you have any questions, please contact your local authority or
waste management company.
Please return this device, accessories and packaging to your local recycling depot. Do not
dispose of electrical appliances in household waste! This satisfies your legal obligations while
also making an important contribution to protecting the environment.
Please note the marking on the different packaging materials and separate them as necessary.
The packaging materials are marked with abbreviations (a) and digits (b) with the following
definitions: 1–7: Plastics, 20–22: Paper and cardboard, 80–98: Composite materials.
12
GB/IE/NI/CY/MT
to make sure that it is not broken or blocked. If there is a
9
, contact an authorised service point.
9
Cause
Power supply interrupted
Cable breakage
Housing is clogged with dirt
Housing is clogged with dirt
Heavy loss in the pipes
Excessive contaminated water
Excessive water temperature
Corrective action
Plug in mains plug
2
Get the cable and pump
checked by the service point.
Clean the pump
in accordance
1
with the instructions in the
"Maintenance and cleaning"
chapter.
Clean the pump
in accordance
1
with the instructions in the
"Maintenance and cleaning"
chapter.
Check for leaks, excessive
height differences, kinked hoses,
etc.
Clean the pump
, fit a filter in
1
the system
Ensure that the water temperature
does not exceed 35 °C.
1

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis