Herunterladen Inhalt Inhalt Diese Seite drucken

Manual Mode; Operational Start-Up; Cleaning/Maintenance/Storage - Parkside PTPS 1100 A1 Originalbetriebsanleitung

Vorschau ausblenden Andere Handbücher für PTPS 1100 A1:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

and lift the loat switch
3) carefully by hand and
(
then lower it again. In this case,
you can see whether the pump
switches on and off.
- Also ensure that the separation
distance between the loat
switch (
switch height adjustment (
is not too small. In the case of a
separation distance which is too
small, trouble-free functioning
cannot be guaranteed.
- During the adjustment of the
loat switch (
the loat switch does not contact
the loor before the pump
switches off.
The pump run dry if too long a loat
switch cable (
particularly if the loat switch height
adjustment (
(see „Initial Operation").

Manual mode

In manual mode, the pump does not switch
off automatically, as the loat switch (
is bypassed.
Position the loat switch (3)
vertically upward in the loat switch
height adjustment (2).
Monitor the pump constantly when
in manual mode. Switch the pump
off immediately (disconnect from
the mains) if no more water is
being pumped. There is a risk of
damage if the pump runs dry.
3) head and the loat
2)
3), ensure that
12) is chosen,
2) is not installed

Operational start-up

• Check that the pump is standing
irmly on the bottom of the shaft
or hung up safely.
• Check whether the pressure line
has been attached correctly and
the unused pump outlet is fully
closed.
• Avoid that the pump runs dry.
Regularly check the function
of the loat switch. In case of
non-observance or if the pump
runs dry, guarantee and liability
claims are invalidated.
• Check that the electrical connec-
tion is 230 V ~50 Hz
• Check the proper status of the
electrical plug socket and make
sure that the plug socket is suf-
iciently fused (at least 6 A, RCD
switch). Insert the pump plug into
the plug socket and the pump is
ready for operation.
• Make sure that moisture or water
never come in contact with the
mains connection. There is a risk
of electrocution.
3)
Cleaning/Maintenance/
Storage
Clean and maintain your equipment regu-
larly. This will guarantee its performance
and long durability.
Ask our service centre to carry out
any work that is not described in
these instructions. Use only original
parts.
This will prevent damage to the
equipment and any resulting per-
sonal injury.
GB