Mains connection

The pump you have purchased is already
equipped with a safety plug. The pump
is intended for connection to an earthed
socket with residual current circuit breaker
(RCCB) with 230 V ~ 50 Hz.
Operation
Adjusting the float
switch
Automatic operation
The on or off switching point of the float
switch ( 1 ) can be adjusted continuously.
1. Disconnect the cable ( 5 ) of the float
switch ( 1 ) from the fastening, if necessa-
ry ( 6 ).
2. Press the cable ( 5 ) in the desired positi-
on into the fastening ( 6 ).
Check the float switch ( 1 ). It must
be positioned so that it can rise and
fall freely. The switching point height
„On" and the switching point height
„Off" must be easily reached.
There is a risk of dry running
if the cable ( 5 ) of the float switch is
chosen too long, especially if the
cable ( 5 ) is not hooked into the fas-
tening ( 6 ) .
Manual operation
The pump runs continuously in manual
operation.
Position the float switch (1), as shown,
directly vertically in the fastening (6).

Switching on and off

1. Open the shut-off valve ( 16 ).
�� Turn in + direction
Use the shut-off valve to regulate the amount
of water that flows into the connected
water hose.
2. Fully immerse the pump.
3. Insert the mains plug in the socket. The
pump starts immediately.
4. To switch off, pull the plug out of the so-
cket. The pump switches off.
If the water level is too low, the
float switch will automatically
switch off the pump.
Supervise the appliance while it is
in operation in order to be immedi-
ately aware if the automatic cut-out
operates or the pump runs dry, to
limit any damage to a minimum.
Maintenance/
Cleaning/ Storage
Clean and maintain your equipment regu-
larly. This will guarantee its performance
and long durability.
Ask our service centre to car-
ry out any work that is not
described in these instruc-
tions. Use only original parts.
There is a risk of injury!
Pull out the power plug before
every maintenance operation. There
is a risk of electrocution or of injury
from moving parts.