Herunterladen Inhalt Inhalt Diese Seite drucken

Assembly; Assemble/Set Spark Protection; Assemble/Set Workpiece Supports; Screw Device On To Workbench - Parkside PSBS 240 B2 Originalbetriebsanleitung

Vorschau ausblenden Andere Handbücher für PSBS 240 B2:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 65
d) Damage to your health caused by
swinging your hands and arms when
operating the appliance for longer pe-
riods of time or if the unit is not held or
maintained properly.
Warning! During operation, this
electric tool generates an electro-
magnetic field which, under certain
circumstances, may impair the
functionality of active or passive
medical implants. To reduce the risk
of serious or lethal injuries, we rec-
ommend that persons with medical
implants consult their doctor and the
manufacturer of their medical im-
plant before operating the machine.

Assembly

Caution! Risk of injury!
- Ensure that you have sufficient
space in which to work, and that
you do not endanger other people.
- Always fasten the device on to
the work surface with screws
featuring the sufficient length and
thickness in order to maintain
control of the device.
- All covers and protective devices
must be assembled properly be-
fore commissioning.
- Disconnect the mains plug before
changing the setting on the device.
Assemble/set spark
protection
1. Screw the spark protection (1)
using the adjusting screw (2) and
the nut (2a) on to the protective
hood (3).
To do so, you will need a screw-
driver and a ring spanner, used
to hold it in place.
2. Set the spark protection (1) with
the adjusting screw (2) so that the
distance between the grinding
disc (19) and the spark protection
is max. 2 mm (see small image).
Periodically readjust the spark pro-
tection in order to offset the wear
and tear of the grinding disc (dis-
tance max. 2 mm).
Assemble/set work-
piece supports
1. Screw the workpiece supports
(6/18) on to the device.
2 positions (see
possible for the tape loop.
2. To do so, use the screws (5a/17a),
washers (5b/17b), toothed lock
washer (5c/17c) and star grip
nuts (5/17) provided.
3. Set the workpiece support of the
grinding belt (19) with the star
grip nut (17) so that the distance
between the grinding belt (19)
and the workpiece support is
max. 2 mm (see small image).
Periodically readjust the workpiece
support in order to offset the wear
and tear of the grinding disc (dis-
tance max. 2 mm).
Screw device on to
workbench
Screw the device onto the work-
bench with 4 screws and nuts.
Insert the screws through the 4 bore
holes (13) on the base of the device.