Herunterladen Inhalt Inhalt Diese Seite drucken

Assembly And Disassembly Of The Connector Cable; Electrical Connection - Selve commeo SE Breeze-com Originalbetriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Installation and electrical connection

3.3. Assembly and disassembly of the connector cable

The connector cable is not yet fully implemented for all motor types; some motor types are
still supplied with a fixed cable.
Attention! Risk of injury from electric shock!
When the connector cable is disconnected, it must be de-energised!
Warning!
To install the connector cable, disconnect it from the power supply. Insert the connector into
the motor head until the lock audibly engages.
To disassemble the connector cable, disconnect it from the power supply. Release the con-
nector lock through the side opening on the motor head. This can be done using a screwdriv-
er or a special release tool. Press on the locking clip from both sides and carefully pull on the
connector cable until the connector comes loose and the cable can be pulled out.

3.4. Electrical connection

Attention: The SE Breeze-com must be connected to a continuous 230 V power supply!
Radio drive without switch,
Connection cable
min. 3-core or 5-core
M 1
~
N
PE
L
1
2
3
PE
L1
N
Radio drive with switch,
Connection cable 5-core
M 1
~
PE
L
4
5
PE
L1
N
N
1
2
3
4
5
0
L
40
1 = PE, yellow/green
2 = L1, brown
3 = DOWN, black
4 = UP, grey
5 = N, blue
Connection of a perma-
nently installed switch is
optional. Connection via
N, L1 and PE is sufficient if
the drive is only to be con-
trolled by radio.