Installation and electrical connection

3.3. Assembly and disassembly of the pluggable cable

The pluggable cable is not yet implemented for all motor types; some motor types are still
supplied with a fixed cable.
Caution! Risk of injury through an electric shock!
When the pluggable cable is unplugged, the line must be de-energised!
Warning!
For installing the pluggable cable, de-energise the pluggable cable first. Insert the plug into
the motor head until the lock engages audibly.
For uninstalling the pluggable cable, de-energise the pluggable cable first. Open the plug lock
through the lateral opening at the motor head. This can be done with a screwdriver or a spe-
cial release tool. Press on the locking clip from both sides and carefully pull out the pluggable
cable until the plug comes loose and the pluggable cable can be removed.

3.4. Electric connection

Attention: The SEE-com must be connected to a continuous 230 V power supply!
Radio drive without switch,
Connection cable
min. 3-core or 5-core
M 1
~
N
PE
L
1
2
3
PE
L1
N
Radio drive with switch,
Connection cable 5-core
M 1
~
N
PE
L
4
5
PE
L1
N
1 = PE, yellow-green
2 = L1, brown
3 = Rotation right, black
4 = Rotation left, grey
5 = N, blue
Connection of a perma-
nently installed switch is
1
2
3
4
5
0
optional. Connection via
N, L1 and PE is sufficient
L
for radio control only.