7.2 Brew group cleaning and degreasing

The brew group is easily cleaned with special brew group cleaning agents.The cleaning is carried out
using the blind filter included in delivery.
Follow the instructions as noted below:
1
Heat up the machine.
2
Place the blind filter into the portafilter.
3
Put approx. 3 - 5g of the group cleaning powder into the blind filter.
4
Clamp the portafilter into the group head.
5
Press the coffee button. The blind filter will fill with water.
6
Press the coffee button in intervals of approx. 20 seconds.
7
Repeat point 6 several times until the water released by the outlet connection is clear again.
8
Remove the portafilter again, rinse it with fresh water and place it back into the brew group.
9
Press the coffee button. The portafilter is filled with water again. Repeat this several times.
10 Remove the portafilter and place a filter into the portafilter. Now the brew group is ready for use again.
Caution!
Beware of hot water while cleaning the group. (Danger of injury).

7.3 Maintenance

Caution!
Make sure that the machine is disconnected from the power supply during maintenance
and when replacing parts.
Replacing the group gasket and the shower screen
1
Switch off the machine, disconnect the power cord and make sure that the machine is cooled down to
room temperature.
2
It is recommended to remove all the removable parts (cup warming tray, water tank lid, water tank,
drip tray), then turn the machine over.
3
Loosen the countersunk screw in the middle of the brew group and the shower plate with an Allen key
(3mm).
4
The shower screen and the shower holder (brass) can be removed easily.
5
Under the shower holder is a thin ring, the gasket of the shower plate.
6
The group gasket can only be removed by inserting a thin screwdriver between shower holder and
group gasket. Pry out the group gasket (the old group gasket will be damaged / destroyed).
7
Clean the groove completely, before installing the new group gasket.
8
When inserting the group gasket, ensure that the bevelled side is facing upwards so that it is no
longer visible.
9
Press the group gasket gradually into the cleaned groove.
10 Then screw in the shower plate and the shower holder.
11
To ensure that the group gasket is inserted properly, carefully clamp a portafilter without a filter into
the brew group.
12 The brew group is ready for use again.